Sök
Code finder
Hitta separata lampor snabbt och enkelt
Advanced search
Hitta den perfekta belysningslösningen snabbare med tekniska filter
Starta sökningen
Välj land
Europa
Nordamerika
Asien
Australia
Om ditt land inte finns med bland de länder som är tillgängliga, kan du gå in på webbplatsen International

EN 60598-2-13

Installation areas for in-ground and linear recessed luminaires

The European standard EN 60598-2-13 defines the areas suitable for installing in-ground luminaires according to the static load, the protrusion from the ground of the diffuser and the temperature of the diffuser itself. These luminaires make it possible to determine whether the luminaire is suitable for specific situations (transit of vehicles, pedestrian pathways, play area etc.). To facilitate luminaire selection, the following pages shows the code of the areas in which installation is permitted, according to the aforementioned standard and the technical specifications, for each individual product.
 

A1 | NO TOUCH AREA

Installation area inaccessible to people and vehicles.

 

Static load (kN) Height (mm) Temperature (°C)
(not applied) (not applied) (not applied)

A2 | WALK-OVER AREA

Installation area with limited access, for example areas for pedestrians only, cyclists only, etc., In no-passing areas, e.G. Near to walls, buildings, etc.

 

Static load (kN) Height (mm) Temperature (°C)
≥ 5 kN ≤ 5 mm / ≤ 25 mm ≤ 100° C

A3 | MOTORABLE AREA

Installation area with limited access, for example areas for pedestrians only, cyclists only, etc.

 

Static load (kN) Height (mm) Temperature (°C)
≥ 20 kN ≤ 75 mm ≤ 80° C

A4 | MOTORABLE AREA PLUS

Installation area accessible to snowplough vehicles or where anti-freeze agents are used, for example, near to walls, buildings, etc. In no-passing areas, e.G. Near to walls, buildings, etc.

 

Static load (kN) Height (mm) Temperature (°C)
≥ 20 kN ≤ 5 mm / ≤ 25 mm ≤ 80° C

A5 | TOUCH WALK-OVER AREA

For example children’s areas, swimming pools, in no-passing areas, e.G. Near to walls, buildings, etc. Where temperatures can cause wounds.

 

Static load (kN) Height (mm) Temperature (°C)
≥ 5 kN ≤ 5 mm / ≤ 25 mm ≤ 40 °C

Products search
You can search for products in our catalog by entering here the name or the code of the product or accessory.